New filtration equipment for nuclear power plants

New filtration equipment for nuclear power plants

Preventing the release of radioactive contaminants into the air remains one of the main factors that determine environmental and radiation safety in the operation of nuclear, radiochemical, and other industries that use nuclear technologies.

This problem remains relevant even when the average levels of gas-aerosol and radio-toxic emissions from nuclear power plants are below the permissible limits, as it does not guarantee the elimination of local deviations in emissions both indoors and in the environment during repair work, overloading of active zones, decommissioning and disposal of equipment, as well as during emergencies and loss of professional control.

FSUE GSC RF Leipunsky Physical and Energy Institute (GSC RF-FEI) as the general developer of filtration equipment for NPP ventilation systems, for several years, performs a complex of research and development works in the following main areas:

  • filtration equipment for existing nuclear power plants: new generation aerosol filters and iodine sorbent filters;

  • filtration equipment for projected nuclear power plants: combined filtration units (UFC) for normal operation and decommissioning of nuclear power plants; passive filtration systems for emergency situations at nuclear power plants.

In addition, work is being carried out on the development of new domestic filter materials and sorbents, as well as the study of promising means and methods of gas-aerosol purification and the behavior of heavy coolant aerosols (lead and lead-bismuth eutectic alloy).

The development of high-tech products became possible thanks to cooperation with scientific departments and enterprises of related organizations with their highly qualified personnel, production facilities, and equipment (FSUE "Russian Scientific Center "Kurchatov Institute" (RSC CI), Moscow Power Engineering Institute (Technical University), the Association of Advanced Integrated Technologies "Aspect", JSC Signal Instrument Factory, Obninsk Center of Science and Technology (OCNT), Filter CJSC (Tovarkovo village, Kaluga Region, Institute of Economics of the Russian Academy of Sciences).

Two-stage aerosol filter FAS-3500-D

Until 1990, the main manufacturer of aerosol filters for NPPs and nuclear industry enterprises was the "Dvigatel" plant (Tallinn, Estonia). The filters produced by it are equipped with a highly effective polymer material – Petryanov FP filter, consisting of layers of polymer fibers with a diameter of d=1.0-2.5 microns, applied to a gauze-like substrate. The originality and uniqueness of this material is associated with the formation of charges on the fibers of the filter cloth, which can be maintained for a long time, providing a relatively high efficiency in capturing particles. The particles are polarized by the fiber's field and deposited on it. However, when moist or ionized air is pumped through the FP filter, the charges are neutralized (or drained), and the efficiency in capturing aerosols decreases significantly. The fibers in the filter are not bonded together, and when moisture enters, they form "rosettes" that are irreversible, as this filter material does not have a rigid internal structure like glass fiber filters. Additionally, it should be noted that the filter has a relatively low heat resistance (60-70°C), a limited lifespan due to clogging, and the release of toxic substances during combustion.

During the 90-ies of the last century, specialists of the Scientific and Technical Center for Nuclear and Radiation Safety (STC NRS) of the State Atomnadzor conducted an inspection of the operation of aerosol filters of the FP type (D-23, D-23kl, A-17), in the systems of special gas purification at the Kursk, Kalinin, Leningrad. nuclear power plants. The analysis of the results obtained shows that the efficiency of the captured aerosol particles for most of the studied filters does not reach the values specified in the technical documentation. In some measurements, the values were unacceptably low. Similar control checks were then carried out at other nuclear power plants, such as the Balakovo, Kola, Zaporizhzhia, and others. The results of these surveys were similar to those obtained at the Kursk, Kalinin, and Leningrad nuclear power plants.

It should be noted that by now, the developers of the FP filter material have made significant progress in improving its technical characteristics, in particular, they have increased its heat resistance to ~300°C. However, the corresponding increase in the cost of manufacturing FP filters has hindered the organization of mass production and, consequently, the equipping of nuclear power plants with these filters.

An alternative to FP filters is the use of glass fiber-based aerosol filters. Filters that use ultra-thin glass fiber paper have a higher efficiency rating. They are heat- and fire-resistant and maintain their efficiency at relatively high humidity levels in the filtered medium, as well as in the presence of alkali and acid vapors.

In the State Research Center of the Russian Federation-Fermi, the development and production of a high-performance fiberglass aerosol filter, which is the main filter for NPP ventilation systems, was carried out in the standard dimensions of the D-23 and A-17 filters using a computational program that takes into account the proposed design solution, which involves switching from a single-stage to a two-stage design /1/. In this case, the ratio of the surfaces of both sections can be varied, taking into account the spectrum and concentration of the captured aerosols in the cleaned environment, as well as the operating parameters.

Studies conducted on the concentrations and dispersive composition of the air in the production facilities of a number of nuclear power plants (Kalininskaya, Balakovskaya, First Nuclear Power Plant, etc.) and radiation-hazardous enterprises show that the concentration of radioactive aerosols can vary widely, from ~0.03 mg/m³ to ~1.0 mg/m³, and the particle size can vary from ~0.2 μm to 5.0 μm or more. If the spectrum is dominated by relatively small particles, the role of the second, highly efficient stage increases, and vice versa, if the spectrum is dominated by relatively large particles, the role of the first stage increases.

Initially, a three-layer glass paper (high-efficiency filter material) of the MFE-3 type was used as the filter material for the high-efficiency purification section. The diameter of the ultra-thin fibers decreased from 0.8 to 0.25 microns as the gas-air mixture was purified. This filter material, obtained using a number of new formulations, was developed jointly with the Research Institute of the Pulp and Paper Industry (Volzhsk, Mari El Republic) and the Glass Plastic Research and Production Enterprise (Kryukovo). Experiments on efficiency and dust capacity showed its advantages over similar foreign samples. However, due to limited demand during the development of this material, its production was never established. Currently, work is being carried out to resume the production of MFE-3 glass paper for the purpose of equipping aerosol filters for nuclear power plants, while simultaneously improving its characteristics related to increased heat resistance up to 200°C and more, hydrophobicity, and improved corrugability.

As a filter material of the first stage, a polyester cloth is used - or a volumetric material made of glass fiber. Two-stage FAS-3500-D filters based on glass paper, Fig. 1, can be manufactured in various versions:

  1. the second-stage glass-paper is laid inside the housing in a zigzag pattern, with spacing using aluminum separators;

  2. The second stage is formed by micro-pleating glass paper, followed by V-shaped stacking inside the housing.

In both versions, the housing can be either wooden or metal, and the pre-treatment section can be removable or non-removable.

Currently, we are developing a version of the FAS-3500-D filter that does not use expensive aluminum separators. By increasing the filtration surface, this design reduces the filter's aerodynamic resistance, which in turn reduces the energy required to pump air and makes it easier to dispose of the used filter.

A comparison of the characteristics of two-stage FAS-3500-D filters and their analogues, single-stage FP filters, shows that the former have several advantages:

  • increased dust capacity (1.5-2 times) and, as a result, longer service life;

  • high cleaning efficiency for the most penetrating particles throughout the entire service life of the filter, including under conditions of ionizing radiation and high air humidity (up to 98.0% at t = 30 );

  • The filter has increased thermal resistance (up to 100°C for extended periods and up to 150°C for up to 4 hours) due to the use of non-combustible and difficult-to-combust filter materials.

Serial production of filters developed at the Russian Federal Nuclear Center-Federation of Atomic Scientists has been mastered by ZAO "Filter" (Tovarkovo, Kaluga Region). Aerosol filters have been supplied to the Kursk, Ignalina, Kalinin Nuclear Power Plants, and a number of radiochemical enterprises.

UFK-3500 Combined Filtration Unit

For NPPs under construction and design, the UFK-3500 combined filtration unit has been developed and created at the State Research Center of the Russian Federation-Fermi Institute, which allows for comprehensive air purification from impurities.

Typically, for existing Russian NPPs, the air in production facilities is purified from various radioactive iodine aerosols and iodine compounds using appropriate aerosol filters and iodine sorbent filters that are spatially separated from each other. This arrangement of cleaning agents is not optimal: due to the "poisoning" caused by aerosols and water droplets, the resource of the sorbent filters is significantly reduced.

In combined filtration units (UFC), one unit provides comprehensive air purification from droplets, aerosols, and radioiodine with the required efficiency.

The UFC-3500 unit is designed for a capacity of 3500 m³/h and includes the following sequentially installed blocks, Fig. 3:

  • capletumano-catcher;

  • heaters;

  • pre-filter for radioactive aerosols;

  • fine (high-efficiency) filter for radioactive aerosols;

  • iodine purification filter consisting of various types of parallel-connected modules.

At the same time, the heater unit guarantees the absence of drip moisture and the required reduction of the relative humidity of the air, and the aerosol filter unit guarantees the absence of a solid dispersed phase in the air entering the iodine purification unit.

Currently, along with the UFK-3500 mock-up installed at the First Nuclear Power Plant, two UFK-3500 pilot-scale units have been manufactured, one of which has been operating at the Kalinin Nuclear Power Plant for over two years. Another prototype, the UFK-3500, has passed the entire test cycle, including seismic tests, and has confirmed its design characteristics.

Tests of the UFK-3500 prototype were performed under conditions of cutting heat-releasing rods, protection control rods and irradiation channels, which ensured the presence of active isotopes (51Gr, 60°C) and active aerosols (239Pu, 240Pu, 238Pu, 241Am, 242, 243, 244Cm) in the gas-air stream with a volumetric activity of up to 4.105 Bq/m3. It has been established that the UFK-3500 provides an efficiency of air purification from aerosols of at least 99.96% for the most penetrating particles, at least 99.90% for molecular radioiodine, and at least 99.0% for methyl iodide (CH3I), which meets the requirements of the General Designer of Russian NPPs.

The data obtained allowed us to provide recommendations for the development and organization of production of a range of combined filtration units with a capacity of 3500, 7000, and 10500 m³/h

The set and number of UFK sections in each specific case is determined by the type and concentration of the expected aerosols and gas impurities in the air. The interchangeable modules of the UFK blocks (sections) are standardized for the entire size range.

Currently, research is being conducted to create UFK-3500 filter modules based on other principles that are more effective than the aerosol section. Positive test results were obtained for a prototype ion-filtration module with a capacity of 1500 m³/h, which makes it possible to replace the pre-treatment section with a similar module and increase the service life of the fine-cleaning section.

The authors

I.V. Yagodkin – Head of the Laboratory of Filtration of Liquids and Gases of the Scientific Research Center of the Russian Federation-FEI, Ph.D.

P.N. Martynov – Head of the Department of the Scientific Research Center of the Russian Federation-FEI, Ph.D.,

A.K. Papovyants – leading Researcher of the Scientific Research Center of the Russian Federation-FEI, Ph.D.,

V.P. Melnikov – leading Researcher of the Scientific Research Center of the Russian Federation-FEI, Ph.D.,

V.P. Osipov – Leading Researcher at the SSC RF-FEI, Ph.D.,

S.S. Skvortsov –Deputy. Head of the Laboratory for Filtration of Liquids and Gases at the Russian Federal Nuclear Center-VNIIEF,

A.M. Posazhennikov – Researcher at the Russian Federal Nuclear Center-VNIIEF,

A.T. Sulim – Chief Designer and Head of the Department at the Russian Federal Nuclear Center-VNIIEF.

Оставить заявку
Оставьте свои контакты и мы свяжемся с вами, чтобы обсудить возможное сотрудничество
Vector 25
Это поле обязательно для заполнения
Это поле обязательно для заполнения
Это поле обязательно для заполнения
Это поле обязательно для заполнения
Это поле обязательно для заполнения
Это поле обязательно для заполнения
Это поле обязательно для заполнения
Спасибо! Форма отправлена
Что-то не так. Попробуйте позже
Сайт недоступен, так как закончился оплаченный период тарифа.
Это ваш сайт?
Оставьте заявку, и специалист свяжется с вами для продления!
Отправить заявку